In recent years, we offers a large number of PLC、RI filter capacitors in AC and DC for HVDC transmission systems, a number of gaps to filled.
330KV Coupling capacitors
DC PLC CAPACITORS
In recent years, we offers a large number of PLC、RI filter capacitors in AC and DC for HVDC transmission systems, a number of gaps to filled.
DEMONSTRATION OF THE TYPE
ZOFF 1-23
In:
Z-DC
O--COUPLING CAPACITOR
F-Impregnant code
F means PXE
A Means M/DBT
F--Solid insulation medium code
F means mixed dielectric of film and paper M means film
1.Rated voltage,kv
2.Rated capacitance,u f
3.Endnote,features code
In the Endnote:
H-Resistance to pollution type products
G-Used for plateau products(Altitude above 2000m area)
F-Using non-solidly earthed neutral systems
ELECTRICAL DIAGRAM
CAPACITOR VOLTAGE TRANSFORMER
MAIN DESIGN FEATURS AND ADVANTAGES
High electric strength. Wide insulation margin
High-quality medium and new structure design application and advanced technology, the electric strength of CVT is improved obviously, guarantee the product operation reliability effectively
Long creepage distance. Strong pollution resistance
The capacitor insulator which the company used has actually long creepage distance, the dry arcing distance is the longest of all, the results of creepage distance/ dry arcing distance is rational. It improves the margin of the outer insulation resistance effectively, enhance fouling resistance.
High accuracy of product. Wide margin
The 11 OkV~ 765kV products can meet the accuracy ofO.l requirements, through the accuracy of characteristic test. Meanwhile the accuracy adjustment tenninal can be lead to outside of product, and adjust the accuracy terminal according to actual needs at location.
High mechanical strength
High mechanical strength capacitor insulator and optimized structure design, it improves product mechanical strength. In the earthquake of Wenchuan, 500kV CVT has operationed at hydropower plant YuZiPingpu which withstood the test.
Good transient response
Damping optimu design, the CVT transient response to 3PTI level, the residual voltage is less than 2%. Can better adapt to requiremeots of fast relay.
Small dielectric loss products. Good PD performance
Reasonable structure of the media and design, advanced technology which can make the dielectric loss (tan 6) reduced to below 0.08%, making the PD performance reduced to below SpC
Good sealability, ensure no leakage
Good seals and optimization structure, second terminal board using lead with SMC overall vacuum pouring parts, which can ensure do not produce oil leakage phenomenon.
ENVIRONMENTAL CONDITIONS
Capacitor voltage transformer (CVT) is widely used in power system 35 kV~ l000kV. Which mainly used for measuring voltage, power and energy metering, simultaneously to the relay protection device and automatic control device provide voltage signal. Which also be used to power line carrier-current collllllunication coupling capacitors and can also be used for the monitoring of the harmonic wave in the power grid voltage.
Structure: single phase, single pillar
Location: indoor or outdoor
Ambient temperature : -40°C~+45°C(Freezing field can meet- 50 "C)
Wind load: not exceed 42m/s
Altitude: not exceed 2000m
Icing thickness: not exceed 10mm
Seismic strength: 8
Pollution level:III or IV
Note: According to user needs, we can provide to meet other special using conditions of the capacitor voltage transformers.
DEMONSTRATION OF TIIE TYPE
TYD -1-2-3
In:
TYD----Capacitor voltage transformer
1—Ratedvoltage, kV
2——Ratedcapacitance, µ F
3-Endnote,features code
In the Endnote·
H-esistance to pollution type products
G-Used for plateau products(Altitude above 2000m areas)
F-Using non-soildly earthed neutral systems
For example: type TYD66/ ✓3 -0.02FH means that this CVT using non-soildly earthed neutral systems 66kV, the capacitance of Capacitor divider is 0.02 µ F, can be used for pollution level III area.