1250kVA 6.6kv 0.4kv Distribution Transformer Power Transformers

1250kVA 6.6kv 0.4kv Distribution Transformer Power Transformers

Back to product >>
Cooperation Consulting >>

Product Details

Power transformer three phase oil immsered electrical transformer rated voltage during 6-35kV, oil immersed transformer are most used in power plant,power grid transmission and distribution station,industry& commerce electrical substation as the electrical equipment of power transmission: 1. Two windings or three windings
2. On-load or no-load voltage tapping changer;
3. Natural cooling or force air or oil cooling;
4. Capacity range 10-2500kVA

 

35KV Oil-Immersed Distribution 
20kV(11KV) SZ11 Series three phases low lose oil-immersed on-load regulation distribution transformer(copper winding)

 

Model NO.: S11-1250/6.6/0.4KV

Cooling Method: Oil-immersed Type Transformer

Winding Type: Two-winding Transformer

 

BASIC INFO.

Model NO. S11-1250/6.6/0.4KV Rated Capacity 1250kVA
Cooling Method Oil-immersed Type Transformer Transport Package Wooden Case or as Per Requirement
Winding Type Two-winding Transformer Specification IEC CE, ISO
Certification ISO9001-2000, ISO9001 Trademark VILLE INDUSTRY
Usage Distribution Transformer Origin Ningbo China
Frequency Characteristics High Frequency HS Code 8504231100
Shape of Core Ring Production Capacity 50000 Sets/Year
Brand Ville    

INTRODUCTION

1. 3Ph,HV:(6,6.3,10.5,11,15KV )  LV:(0.415,0.4,0.69 KV)
2. Rated Capacity:10kVA~20MVA
 
Transformer Standard
GB  1094.3-2003( IEC 60076-3-2000) 
 
Service Condition
1) Altitude: ≤1, 000m
2) Maxl ambient temperature: +40.C
3) Maxdaily average temperature: +30.C
4) Maxannual average temperature: +20.C
5) Minimal ambient temperature: -25.C
6) Indoor or outdoor 

2 (23)

DATA SHEET

Tech data of 10kV SZ11 series on-load regulation distribution transformer
Rated capacity Voltage group Vector group Impedance voltage Loss(kW) No-load current (%) Weight(kg) Outline Gauge vertical/
(KVA) (kV) (%) No-loss Load Body Oil Total dimension (mm) Horizontal
200 (HV)   6-15kV (LV) 0.415-6kV Yyno Dyn11 4 0.34 3.06 1.5 540 270 1110 1400*740*1190 550/550
250 0.4 3.6 1.4 640 290 1270 1420*790*1210 660/660
315 0.48 4.32 1.4 730 320 1500 1540*850*1240 660/660
400 0.57 5.22 1.3 940 370 1780 1590*940*1250 660/660
500 0.68 6.21 1.3 1040 370 1920 1650*1000*1350 660/660
630 4.5 0.81 7.65 1.1 1220 460 2280 1810*1140*1350 820/820
800 0.96 9.36 1 1500 500 2740 1890*1200*1310 820/820
1000 1.15 10.98 1 1610 520 3060 1910*1260*1570 820/820
1250 1.36 13.05 0.9 1880 700 3710 1960*1280*1740 820/820
1600 1.64 15.57 0.8 2290 780 4350 2330*1800*1910 820/820
2000 1.96 21.26 0.8 2560 900 4950 2580*1900*1950 820/820
2500 2.31 24.69 0.7 3170 1010 6020 2580*1940*2250 1070/1070
Note:it can supply voltage regulating range of ±4*2.5%for HV on load regulation transformers