capacitor to restrain the distortion of grid voltage waveform, so as to change the quality of power grid and ensure
the safe operation of power system; to restrain the harmonic current flowing through the capacitor bank and limit
the closing inrush current, so as to protect the capacitor and make it operate safely and reliably.
Ck Dry Type Air-Cored Series Reactor for 6kv 10kv 35kv Power System
Model NO. | CK |
Usage | Suppression of Voltage Waveform Distortion |
Filter | Customized |
Transport Package | Standard Export Wooden Case |
Trademark | VILLE |
HS Code | 84 |
Electrolyte | Dry Type |
Tuning | Glass Membrane Capacitor |
Voltage | 6,10,35kv |
Specification | As per drawing |
Origin | China |
Production Capacity | 50000 Sets/Year |
Product Description
Introduction to Product
Dry type air core series reactor is suitable for 6,10,35kv power system, which is connected in series with shunt
capacitor to restrain the distortion of grid voltage waveform, so as to change the quality of power grid and ensure
the safe operation of power system; to restrain the harmonic current flowing through the capacitor bank and limit
the closing inrush current, so as to protect the capacitor and make it operate safely and reliably.
Dry type air core series reactor is suitable for 6,10,35kv power system, which is connected in series with shunt
capacitor to restrain the distortion of grid voltage waveform, so as to change the quality of power grid and ensure
the safe operation of power system; to restrain the harmonic current flowing through the capacitor bank and limit
the closing inrush current, so as to protect the capacitor and make it operate safely and reliably.
Feature:
1. The reactor adopts dry air core structure to avoid oil leakage, flammability and other defects of oil immersed
reactor. It has simple maintenance, safe operation, no iron core, no ferromagnetic saturation, inductance value
will not change with current change, good linearity and low noise.
2. The reactor coil is encapsulated by epoxy resin impregnated weft free glass ribbon. The reactor coil adopts
polyester film and glass fiber with excellent insulation performance as the turn to turn insulation of conductor.
3. The surface of reactor is covered with silicon organic paint which is resistant to ultraviolet radiation, which has
good outdoor weather resistance performance.
4. Polyester glass pull-out rod is used as axial cooling air passage for reactor, which has good heat dissipation
performance.
5.The maximum temperature of the reactor is taken into account to ensure the safety of the reactor during long-term
operation.
6. Because the reactor adopts multi-layer parallel structure, the axial electric stress of the coil is zero, and the voltage
distribution along the coil axial height direction is uniform under steady-state operating voltage.
7. Since the reactor is wrapped with non weft glass ribbon impregnated with epoxy resin, the coil has good integrity
after curing treatment, and the noise level of reactor is lower than 60dB during the whole service life.
8. The reactor adopts aluminum conductor (Φ 1.5 ~ Φ 5) with small cross section as coil conductor, which effectively
reduces eddy current loss in the conductor under harmonic state.
9. Because the reactor is wrapped with epoxy resin impregnated weft free glass ribbon, the huge mechanical force
generated when the reactor passes through the short circuit current is borne by the enveloping, so that the whole
coil has a very high ability to resist short circuit current.
10. The conductive part of reactor is welded by argon arc welding, and there are no fastening parts on the mechanical
structure, which greatly improves the operation reliability.
11. The whole reactor has a simple and compact structure and can operate for a long time under outdoor climate
conditions without equipment maintenance requirements.
Technical specification:
Please provide below parameters while ordering:
1. Rated frequency;
2. System voltage;
3. Rated capacity of matching capacitor bank;
4. Rated voltage of matching capacitor;
5. Rated reactance or reactance rate of reactor;
6. Insulation level;
7. Insulation heat resistance grade;
8. Place of use: indoor or outdoor;
9. Installation mode and angle of incoming and outgoing lines;
10. Other special requirements.
Using environment:
1. Place of use: outdoor or indoor, indoor use should pay attention to ventilation and heat dissipation.
2. Ambient temperature: - 40 ~ 45 ºC.
3. Relative humidity: monthly average not more than 90%, daily average not more than 95%.
4. Maximum wind speed: no more than 30m / s.
5. Altitude: no more than 1000m (more than 1000m shall be stated when ordering).
6. Seismic capacity: it can withstand earthquakes with intensity of 8.
7. There should be no severe vibration or turbulence in the installation and operation area.
8. The installation and operation area shall be free of harmful gas, steam, conductive or explosive dust.
(if there are special requirements, please indicate when ordering.)
Our Services
1. |
Pre sale service |
a. |
make technical solution |
b. |
send quotation, technical data sheet and drawing |
c. |
prepare power transmission plan, testing plan and shipment plan |
2. |
In sale service |
a. |
supervise the manufacturing schedule totally in accordance with the plan |
b. |
send photos to customer during every manufacturing process(hold point) |
c. |
inform the customer one week before testing. |
3. |
After sale service |
a. |
installation and commissioning, training the workers |
b. |
quick response within 12 hours any time |
c. |
provide 12 months guarantee period normally. |
FAQ
1. Q: |
What is your delivery time ? |
A: |
Depend on the type of transformer. |
2. Q: |
What is your payment term? |
A: |
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it. |
3. Q: |
What kind of standard you follow? |
A: |
IEC, ANSI, CSA, GB, etc |
4. Q: |
What kind of supporting documentation you can provide normally |
A: |
Quotation, outline drawing, manufacturing plan, quality control plan |
5. Q: |
What is your normal warranty period? |
A: |
12 months after transformer operation. |
6. Q: |
Can u do installation and commission in user's site? |
A: |
Yes, we can send our installation team to user's country for service. |
7. Q: |
Do you have any experience in this kind of transformer? |
A: |
Yes, we can provide reference list for check. |
Our Services:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
Global Service
--Wherever you are, VILLE global network will support and provide you with value.
Quick Response
--In response to your needs without delay, VILLE knows the value of your time.
Thanks for choosing VILLE as your reliable partner and please trust both of us will create a brilliant future!