One Step Solution For Transformers
Product Details
Low-voltage shunt capacitor is mainly used in power grid with voltage below 1kV and power frequency of 50Hz. To improve power factor, reduce reactive power loss and improve power quality.
(1) Aluminum stretch shell, high mechanical strength, good heat dissipation;
(2) The bottom screw installation mode is simple, convenient and multi-directional;
(3) Vacuum filling technology, no leakage risk, safe and environmental protection;
(4) High reliable insulation characteristics;
(5) Low loss and low temperature rise;
(6) Built-in discharge resistor and over-pressure safety device.
(1) Indoor use;
(2) Ambient temperature: - 25 ℃~+50 ℃ (higher temperature can be specially designed);
(3) Ambient humidity: ≤ 90%;
(4) Altitude: ≤ 2000m (higher altitude can be designed separately).
(1) Rated voltage: 230~800VAC (50Hz);
(2) Rated capacity: 5~40kvar;
(3) Capacity deviation: ± 5%;
(4) Loss angle tangent angle: less than 0.0015;
(5) Maximum allowable overvoltage: 1.1Un;
(6) Maximum allowable overcurrent: 1.3ln;
(7) Discharge characteristics: drop below 75V within 3 minutes after disconnecting the power supply;
(8) Test voltage: 2.15Un between poles, 5S; Pole shell 3000VAC 10S;
(9) Installation method: vertical installation;
(10) Conforming standards: GB/T12747-2004, IEC60831-1996.
Related Products
-
Ferroalloy Furnace Transformer with off-circuit tap changer
Ferroalloy Furnace Transformer with off-circuit tap changer
Voltage: 10kv /35kv /110kv
Capacity: 2.5MVA-16MVA¥ 0.00Learn more>>
-
Single Phase Yellow phosphorus furnace transformer
Single Phase Yellow phosphorus furnace transformer¥ 0.00Learn more>>
-
Yellow Phosphorus Furnace Transformer with On load tap changer
35kv Yellow Phosphorus Furnace Transformer with On Load Tap Changer
capacity:6.3MVA-80MVA¥ 0.00Learn more>>
-
Yellow Phosphorus Furnace Transformer
Yellow Phosphorus furnace transformer with off circuit tap changer¥ 0.00Learn more>>
-
Reactor
We mainly design and produce reactors concerning balanced reactor and neutral point reactor.The manufacturing technique and level are critical to the product.We process advanced manufacturing technique and large processing machine,ensuring to provide products with excellent performance.¥ 0.00Learn more>>
-
Ladle Refining Furnace Transformer with off circuit
Ladle Refining Furnace Transformer with off circuit
Voltage:6kv 10kv 35kv
Capacity:3150kva ~8000KVA¥ 0.00Learn more>>
-
Ferroalloy furnace transformer with off-circuit tap-changer
Ferroalloy furnace transformer with off-circuit tap-changer¥ 0.00Learn more>>
-
Electroslag Remelting Furnace Transformer
Electroslag Remelting Furnace Transformer
Primary Voltage: 380V,6KV ,10KV,35KV
Secondary Voltage: 30V~140V
Voltage Regulation Type: Off circuit tap changer or On load tap changer¥ 0.00Learn more>>
-
Three phase power frequency induction furnace transformer
Three phase power frequency induction furnace transformer
Voltage: 10kv 35kv
Capacity: 160KVA ~6300KVA¥ 0.00Learn more>>
-
ladle refining furnace transformer with on load tap changer
ladle refining furnace transformer with on load tap changer
voltage:35kv 110kv
capacity:10mva ~63mva¥ 0.00Learn more>>
-
Ferroalloy Furnace Transformer with on load tap changer
Ferroalloy Furnace Transformer with on load tap changer
Voltage:35kv 110kv
Capacity:6.3MVA-30MVA¥ 0.00Learn more>>
-
Electrothermal capacitor,Electric capacitor for improving power factor of induction heating
1500kvar 750v Electrothermal capacitor,Electric capacitor for improving power factor of induction heating 14.62uf
Rated power :1500KVAR
Rated Voltage: 750V
Rated frequency: 500HZ
Capacitance:14.62uf(-5%-+10%)
Rated Current: 2000A
Approximate Weight: 28kg¥ 2800.00Learn more>>
-
JW10系列
¥ 0.00Learn more>>
-
GW23B系列
¥ 0.00Learn more>>
-
GW22B系列
¥ 0.00Learn more>>
-
ZT series neutral grounding resistance cabinet for transformer
¥ 0.00Learn more>>