Electric furnace transformers are transformers which supply power to the electric furnaces. It can drop high
voltage to the working voltage the electric furnaces need.

144mva 35kv Furnace Transformer for Metallurgical Electric Arc Furnace Transformer, 30mva Reactor Power Supply Steel Industrial Furnace

Back to product >>
Cooperation Consulting >>

Product Details

Model NO. HSSPZ-144000/33
Winding Type Multi-winding Transformer
Frequency Characteristics Power Frequency
Brand Ville
Steel Furnace
Test Certification Kema
No Load Losses 52kw
Cooling System Ofwf, Double Tube, 2 Coolers in Service.
Testing -Routine Test According to IEC Standard
Specification IEC
Origin Ningbo China
Production Capacity 10/Years

 

Cooling Method Oil-immersed Type Transformer                        
Usage Electric Arc Furnace Transformer
Shape of Core Ring
Arc Furnace Transformer
Type Calcium Carbide Furnace Transformer
Reference Standard IEC 60076
Load Losses at 75 280 Kw ( 60mva 950V ) (Including LV Lead Losses
on-Load Tap Changer Mr
Transport Package Nuke Packing; Wooden Cases
Trademark ville
HS Code 8514901000

 

 

Product Description

Electric arc furnace transformer

Main function and characteristic

Electric furnace transformers are transformers which supply power to the electric furnaces. It can drop high
voltage to the working voltage the electric furnaces need.

There are many kinds of electric furnaces,so there are many kinds of electric furnace transformers cooperating
with them.Now,our company manufactures following electric furnace transformers:electric furnace transformers
used in steelelectric furnaces(including on-laod,no-load and enclosed reactor) ; mineral hot furnace
transformers used to smelt kinds of iron alloys,hydrosilicons,carbides,etc(single phase,three phases on-load
and no-load tap changer).They are low loss and energy-saving products.Cooling methods are self-cooling,
forced oil water cooling, etc.It can be designed specially according with customers' requirements.

The model of the electric furnace transformer is expressed as follows:

 

The meaning of model:

H--Steelmaking arc furnace,HJ--ladle furnace,HZ--electro-slag furnace,HC--calcium carbide furnace,HK--mineral
hot furnace,HG--line frequency induction furnace;

Number of phase:D--single phase,S--three phase;

Types of cooling device :ONAN,wind cooling F,water cooling S.

The methods of oil circulation:natural circulation,forced oilcirculation P.

Tap changer:off-circuit tap changer,OLTC Z.

Enclosed attached device:changing leakage flux,enclosed reactor K.

Rated capacity:KVA. max 140MVA 

Voltage class:KV. 35KV

Product reference:

 

  •  

 

 

1.1.2 TRANSFORMER DATA
General data  
Operating Voltage  33KV±3%
Frequency  50Hz±1%
Rated capacity  144 MVA
Over load power 144MVA plus 20%,30 min.
Rated primary current  1049.7 A
Insulation Level (AC/LI) 85/200 kV
Vector group  D/d0 with booster regulation transformer inside.
Secondary connection  Delta OPEN 
System short circuit capacity at 33kV side. 1100 MVA
Secondary outlet  Terminals with Bus bars come out from  top cover. 8 Buss bars  by 
epoxy resin arranged  along with each phase with matching cite 
transformer sizes.
Max. Secondary current  Approximate  42120 A
Secondary voltage range  950-500 V. 
a) Constant power  950V-822.4 V at 60 MVA
b) Constant current  About 42062 A within 824V-500V
c) Short-circuit voltage  8 % (at 950V,60MVA) 
Type of tap changer  On load tap-changer:  
a) Manufacturer  MR,
b) Number of tapes  17 voltage steps with 18position See attached data sheet of 60
MVA EAF transformer.
c) Oil filter equipment for OLTC              yes
Cooling  OFWF

 

Cases reference:

 

PACKING AND SHIPPING:

 

Our Best Service For You

1. Pre sale service
a. make technical solution
b. send quotation, technical data sheet and drawing
c. prepare power transmission plan, testing plan and shipment plan
2. In sale service
a. supervise the manufacturing schedule totally in accordance with the plan
b. send photos to customer during every manufacturing process(hold point)
c. inform the customer one week before testing.
3. After sale  service
a. installation and commissioning, training the workers
b. quick response within 12 hours any time
c. provide 12 months guarantee period normally.


Order Instructions
When you choose our company product, please offer following data:
Transformer model:                     
Rated capacity:                     kVA
Phase:   Three-phase
              Single-phase
Frequency:     50HZ
                       60HZ
Rated voltage ( H.V. / L.V. ):                
Tapping range: ±       ×       %
Insulation level: LI       AC       / LI       AC        kv
Veotor group:  Dyn11
             Yyno
             Other
Short-circuit Impedance:        %
Cooling method:  ONAN
                ONAF
Tapping method:  OLTC
                OCTC
                Other
Other requirement:                                            

Notes:
We also can design special products according to customer's particular requirements.
The final dimension is subject to outline drawing.