控件[tem_25_34]渲染出错,Source:未将对象引用设置到对象的实例。
Series Reactors are used in Electric Arc Furnaces (EAF) to provide furnace operation with longer arcs, lower currents and lower electrode consumption. Such reactors are very useful in the first melting period. With the molten scrap, the absence of the series reactor would allow higher power transfer to the EAF, reducing the tap-to-tap cycle, thus increasing productivity.

18000kvar Arc Furnace Oil Immersed Reactor Iron Core Series Oil Immmersed Reactor, Power Reactor

Back to product >>
Cooperation Consulting >>

Product Details

Model NO. XKSSP-18000/33
Winding Type Multi-winding Transformer                                     
Usage Series Furnace Reactors
Shape of Core Ring
Transport Package Wooden Case
Trademark ville
HS Code 85

 

Cooling Method Oil-immersed Type Transformer
Certification ISO9001-2000, ISO9001                                                                  
Frequency Characteristics High Frequency  
Brand Ville
Specification IEC                                              
Origin China            
Production Capacity 50000 Sets/Year     

 

 

Product Description

Series Reactors are used in Electric Arc Furnaces (EAF) to provide furnace operation with longer arcs, lower currents and lower electrode consumption. Such reactors are very useful in the first melting period. With the molten scrap, the absence of the series reactor would allow higher power transfer to the EAF, reducing the tap-to-tap cycle, thus increasing productivity. This paper proposes an active series reactor based on static power converters, which has the flexibility to dynamically change its impedance value during the steel production period. Simulation of a real plant demonstrate the effectiveness of the proposition.

 

 

1.1.1 GENERAL TECHNICAL DATA  
Highest voltage      36kV 50Hz
Operating voltage   33 kV±5% 50Hz
Voltage for aux. drivers    380V 50Hz
Control voltage     220V 50Hz
Interlock voltage   220V 50Hz
PLC signals       24V DC
Ambient temperature max./min. 45 / - 10 Deg. C
Altitude 1500 m
Humidity 80 %
1.1.2 TRANSFORMER DATA   
Operating voltage   33kV±5%
Frequency    50Hz  ±1%
Operation     Continuously
EAF transformer rated capacity     MVA (+ 20% Overload)
Rated current      2449.4 A    (+ 20% Overload)
Reactor Rated Power 18 MAVR  (25.92 MVA Overload)
Reactance in normal tap 1 Ω
Number and ratio of taps  6 taps:
100%-80%-60%-40%-20%-0
Insulation level
Winding:
Um:
AC:
BIL:
Full insulation
HV         
52 kV       
95 kV       
250 kV      
Protection level        IP54
Vector group          III 
System short circuit capacity    1500 MVA
Short circuit duration 6 sec
Short circuit times 2.5 times
Regulation method  Off circuit
Type of tap changer           NLTC  Off -circuit  motor drive
Manufacturer             Shanghai Huaming / China (ZUNYI)
Model       2*ZWL III-1600/40- 6 taps
Number of taps 6
Reactor Winding Materials Copper
Cooling Type OFWF   

 

 

 

 

Related Products

PRODUCTS

Product consulting

Consulting products: *

Name: *

E-mail: *

Contact number: *

WeChat: *

Notes: *

控件[tem_25_34]渲染出错,Source:未将对象引用设置到对象的实例。